What is really happening when a well stops delivering
A well system is four things working in series: a motor and pump hanging on a
string of pipe hundreds of feet underground, a cable feeding it power, a
pressure tank that stores a buffer so the pump is not starting every time you
wash your hands, and a switch that decides when to run. When water stops
arriving at the sink, one of those four has failed, or the water level itself
has moved out from under the intake.
That last possibility is the one people never consider, and around Visalia it is
the one we confirm most often. The pump is fine. It is drawing correct amps, the
windings test clean, the wire is sound. It is just no longer deep enough.
Losing prime versus losing water
The difference is audible. A pump that has lost prime, a failed check valve, a
pinhole in the drop pipe, a jet pump that has drained back, will run smoothly
and build nothing. A pump that is running out of water surges: pressure holds,
then breaks, then partially returns as the well trickles back in. If the faucet
sputters air in bursts rather than going flat, the well is telling you the water
is down at the intake.
Telling the three common failures apart
The pressure tank
Grab the gauge and watch a cycle. Pressure jumping from cut-in to cut-out and
back every twenty to forty seconds while one tap runs is a waterlogged tank. The
rubber bladder has failed and there is no air cushion left, so the pump starts
and stops constantly. This is the single most common reason we pull perfectly
good pumps that were killed young, a motor rated for a few hundred starts a day
was being asked for several thousand.
The controls
Pressure switch contacts pit and burn. Three-wire systems have a control box on
the wall holding the start capacitor and relay, and those fail long before the
motor does. A burnt smell near the switch, a breaker that trips faster on each
reset, or a pump that hums but will not turn over usually lands here. These are
the cheapest repairs on a well system and the ones most often misdiagnosed as
“the pump is shot.”
The pump itself
Worn impellers show up as a system that builds pressure slowly and never quite
reaches cut-out. Sand in the toilet tank means the stages are eroding or the
intake is too near the bottom. A dead short down the cable, or insulation
resistance that reads low on a megger, means the motor or the wire is finished
and the pump is coming out.
Why the same well keeps failing
If you have replaced a pump twice in eight years, the pump was not the problem.
Three conditions destroy well pumps prematurely here, and all three are fixable.
Short cycling on a dead pressure tank hammers the start windings. Running dry
because the intake is above the pumping level in summer removes the only cooling
the motor has. Pumping sand grinds the stages open until the pump cannot make
head. Replace a pump without correcting whichever of those is present and you
have bought yourself the same failure on the same schedule.
This is why we measure static level and drawdown on every well call, even when
the customer has already decided the pump is bad. Ten minutes with a sounder
frequently saves the full cost of a pump that did not need replacing.
What it costs, honestly
Diagnosis comes first and the fee is credited against the work. Pressure
switches and control box repairs sit at the light end of the scale. A
pressure tank replacement costs more,
depending on size and how the piping was originally put together.
Pump work is where the numbers move, and depth is the biggest driver. A shallow
jet pump above ground is the smallest of these jobs. A submersible replacement
at a common local depth, pump, motor, cable, drop pipe, torque arrestor, check
valve, splice and disinfection, is a substantially bigger one. Deeper sets,
larger horsepower, three-phase equipment or a well that has to be cleaned
before anything goes back in push past that, and we will say so before you
commit.
Lowering an existing healthy pump into deeper casing, where there is casing to
use, costs a fraction of a replacement, which is why that measurement happens
first. Whatever the readings point to, you get the exact number in writing
before any work starts, and it does not change unless you approve a change.
Where our license stops
We are a licensed plumbing contractor, CSLB #1072777, working out of Exeter and
about twenty minutes from most Visalia addresses on Highway 198. Pumps, tanks,
controls, wiring, drop pipe and every line from the wellhead into the house is
our work. Drilling a new well, deepening an existing one, or destroying an
abandoned one is C-57 territory and permitted through Tulare County
Environmental Health.
If your problem is the equipment, we fix it and you get a price before the truck
door closes. If your problem is that the aquifer has moved, we will tell you
that instead, and you will have real numbers to hand the driller.