Two contaminants that give you no warning at all
Almost everything else a plumber deals with announces itself. A slab leak makes a warm spot on the tile. A failing water heater rumbles. Hard water writes its name on the shower glass.
Nitrate and arsenic do none of that. There is no taste, no smell, no color, no cloudiness, no sediment in the aerator. A well can sit two points over the state limit for a decade while the family drinking from it notices nothing whatsoever. The only way anyone ever finds out is a laboratory result on a piece of paper.
That is the whole reason this page exists, and it is why our first answer to almost every caller is the same: get it tested before you buy anything.
What each one actually is
Nitrate
Nitrate is a nitrogen compound, and in Tulare County it is agricultural and residential in origin, fertilizer applied to row crops and orchards, dairy corrals and lagoons, and rural septic leach fields. Applied irrigation water carries it downward into the shallow aquifer over decades.
The maximum contaminant level in California and under the EPA is 10 milligrams per liter measured as nitrogen. You will sometimes see the same water described as 45 mg/L, which is the identical concentration expressed as the nitrate ion. Confirm which unit your lab used before you panic or relax.
The recognized concern is for infants under six months and during pregnancy. We are not going to describe the mechanism here, because that is a conversation for your doctor and for the county health department, not for a plumbing contractor. What we will say plainly: if there is a bottle-fed baby in the house and you have never tested, use bottled water today and test this week.
Arsenic
Arsenic in the San Joaquin Valley is not a spill or a leak. It is in the sediment the aquifer sits in, released into the water by natural chemistry, and it has been there far longer than any farm. The limit is 10 micrograms per liter, a much smaller number than the nitrate limit, in different units, which is another reason reports get misread.
Arsenic also comes in two chemical forms. Arsenate is charged and comparatively easy to capture. Arsenite is uncharged at normal groundwater pH and passes through activated alumina and anion exchange almost untouched unless it is oxidized to arsenate first. Wells with a sulfur smell or dissolved iron are the ones most likely to carry arsenite. This is not a detail you can skip, it is the difference between a system that works and a very expensive tank of media doing nothing.
How to tell which problem you have
You cannot, without a lab. But you can predict the odds.
Shallow well, ag ground nearby, under about 150 feet. Nitrate is the likely finding. Test it annually.
Deep well, or a well that was recently deepened or had its pump reset lower. Arsenic becomes the more likely finding, and it should be tested even if nitrate came back clean.
A well that was fine ten years ago and has never been retested. Both. The water table across the county has dropped substantially, wells have been chasing it, and the zone your pump draws from today may not be the zone it drew from then.
On Cal Water inside Visalia. Read your annual report first. The utility is required to test and treat, and for most in-city addresses this is not your problem.
Why one clean test does not settle it
Nitrate in shallow valley groundwater moves. A wet winter flushes the upper soil profile and can push a slug of it down into the producing zone. A heavy summer irrigation set does the same thing on a smaller scale. Seasonal pumping changes which part of the aquifer your well is pulling from.
We have seen the same well read 7 mg/L in autumn and 11 mg/L the following June. Neither number was wrong. A result at 8 is not a comfortable pass, it is a reason to sample twice a year rather than once.
What treatment honestly costs
Testing first, because it is cheap next to any equipment and it is the only thing that makes the rest of the decision rational. Our sampling call, lab panel and courier are quoted up front, and that charge is credited back if you proceed with treatment.
An under-sink reverse osmosis system, which reduces both nitrate and arsenate and is where most households here should start, is the smallest install, with a small annual consumables cost.
Whole-house treatment is a different scale of job. Nitrate-selective anion exchange needs a drain, an outlet and a salt supply, arsenic adsorptive media carries a periodic media change, and pre-oxidation adds work if your arsenic is in the arsenite form. Which of those your well needs, and therefore what it costs, comes straight from the lab report, and the figure goes to you in writing before anything is installed. It does not move unless you approve a change.
Whatever goes in, we sample the treated water afterward and send it to the lab. A treatment system for a health-based contaminant that has never been verified in service is a hope, not a solution, and you paid for a solution.