No water at all: check these in order
When the whole house loses water on a well system, the cause sits in one of three places: the power, the controls on the surface, or the pump and the water down the casing. You can narrow it from the house in a few minutes without opening anything live.
- Find the well breaker. It is usually a double-pole breaker in the main panel, often labelled well or pump. If it has tripped, reset it once. If it trips again, leave it off. Repeated resets on a shorted cable or a seized motor make the damage worse.
- Read the gauge at the pressure tank. Zero, with the pump silent, points to power or the pressure switch. A gauge at a normal reading while the faucets run weak points to a clogged line or filter inside the house instead.
- Listen. If the pump runs but the gauge will not climb, water is not reaching the tank. Switch the breaker off, because a submersible running without water overheats quickly.
- Watch the faucet when water comes back. Spitting air and then sand suggests the water is near the pump intake or the pump is worn. Rapid on-and-off clicking with a decent supply is usually a waterlogged or failed pressure tank, which is a different visit.
Do not open the pressure switch cover or the control box with power on. Both can carry 240 volts.
Inside Tulare city limits, the well is a permit question first
Some calls come from inside the city, from a house that still has an old well in the side yard next to its City service. Here the order of work changes, because Tulare’s Well Ordinance, Chapter 7.09 of the Municipal Code, governs what can be done.
The ordinance makes it unlawful to construct, modify, repair, abandon or destroy a well in the city unless the Public Works Director has permitted the work. It refuses permits for new wells on property inside city limits, already connected to City water, or within 500 feet of a feasible connection point, and it bars most modifications in those same areas. A well that has gone a year without maintenance or use counts as abandoned. Any property that has a well and City water together must also have an RP backflow assembly at the City meter, tested every year at the owner’s cost, and installing that assembly is a job in its own right.
So before we pull a pump on a Tulare lot, the first question is whether the City will permit the work at all, or whether closing the well properly is the better path. We will tell you how it looks from the wellhead. Public Works makes the call.
One aquifer, two ways of drawing on it
The City of Tulare takes every gallon it serves from wells in the Kaweah Subbasin, a 696-square-mile basin the state has designated critically overdrafted. The City holds no surface water rights. It buys Tulare Irrigation District water purely to recharge the aquifer, 2,344 million gallons of it in 2020, and holds a 75 percent interest in the Swall recharge basin upgradient of town. Its water plan reports that City groundwater levels were falling before the drought years and have since begun to stabilize.
A rural domestic well pumps the same groundwater without being part of that municipal arrangement. When a pump that worked for years starts pulling air in late summer, the water level near its intake is one of the first things we check, with a sounder rather than a guess.
If dropping water levels turn out to be the problem, there is a local process for it. The Mid-Kaweah Groundwater Sustainability Agency, formed in 2015 by the City of Tulare, the City of Visalia and Tulare Irrigation District, adopted a mitigation plan in July 2024 for domestic wells harmed by declining groundwater, and it sends owners and renters with supply trouble to Self-Help Enterprises first. Whether your well qualifies is their question to answer, not ours.
What comes up out of the casing
When the evidence points down the well, the pump comes out, with the drop pipe and power cable lifted together. What we find usually tells the story:
- A burned or nicked wire splice. Often the entire fault, and repairable.
- Impellers worn by sand. The pump has been running near the bottom of its water, or the well makes sand.
- A failed check valve. The system bleeds pressure between cycles and the pump restarts again and again.
- Corroded or split drop pipe. Water circulates back down the well instead of reaching the tank.
We show you the parts before deciding anything. Sometimes the answer is a new pump set at a different depth. Sometimes it is a splice and a check valve.
After the pump runs again
Opening a well can let bacteria in, so once the work is done we disinfect the well and the household lines, flush them clear, and recommend a bacteria test before the family drinks from it. If that test, or a fuller panel, shows something worth treating, treatment chosen from the lab results is the next step. We also log running amps, the pressure switch settings and the water level we measured, so the next call around Tulare starts with numbers instead of guesses.