The TDS pen trick, and Tulare’s real number
You may have seen this demonstration. A salesperson dips a small meter into a glass of your tap water, reads out a number, then dips it into bottled water that reads close to zero. The gap is supposed to worry you.
That pen measures total dissolved solids, which are mostly ordinary minerals and salts. In Tulare’s 2025 report, TDS averaged 151.5 mg/L across samples that ran from 86 to 340, and the secondary standard it is measured against is 1,000. Sodium averaged 37.2 mg/L, chloride 10.3 and sulfate 7.8, and pH averaged 8.5. That is low-mineral water. A TDS pen cannot single out arsenic, nitrate or uranium, so a low reading does not prove they are absent and a higher one does not prove anything harmful is present.
So in Tulare, reverse osmosis is not a cure for salty or heavy water, because the City’s water is neither. It is a tool for a narrower job.
The rows of the report a membrane can move
That narrower job is lowering specific constituents the City detects below their legal limits, at the one tap you drink and cook from. These are the 2025 rows people ask about most. Each was reported with no violation, and each range shows individual sample results.
| Constituent |
2025 average |
Range |
Legal limit |
| Arsenic |
3.8 ppb |
ND to 11 |
10 ppb |
| Nitrate (as N) |
3.9 ppm |
ND to 7.9 |
10 ppm |
| Uranium |
1.73 pCi/L |
ND to 3.20 |
20 pCi/L |
| Hexavalent chromium |
1.9 ppb |
0.05 to 2.8 |
10 ppb |
| Gross alpha |
2.0 pCi/L |
ND to 5.8 |
15 pCi/L |
A household that reads those figures and wants them lower in drinking water has a reasonable option in RO. A household satisfied with water that meets every primary standard has a reasonable option in doing nothing. We will not push you either way, and we will not tell you what a number means for anyone’s health. That question belongs to the City’s report and your doctor.
One gap is worth knowing. The City took part in federal UCMR5 sampling for PFAS but printed no results in its 2024 or 2025 reports, and says the data is available on request. If PFAS is your reason for buying, ask the Water Division for it, and choose a unit certified for PFOA and PFOS reduction.
Matheny Tract and the well-water exception
Two miles south of the city, Matheny Tract was served by Pratt Mutual Water Company. In 2010 two of its wells exceeded the arsenic standard, and the State issued a compliance order that December. Under SB 88 the State Water Board’s Division of Drinking Water ordered the system consolidated with Tulare’s, the first mandatory consolidation the Division had issued in California. By 2016 the arsenic wells were closed and residents were City customers.
For anyone on a private well around Tulare, the lesson is to test before you treat. We hold no data on rural wells, and nobody can tell you what is in yours without a certified lab. If arsenic does show up, its form matters. RO units certified for arsenic are tested against the pentavalent form, which chlorine produces, and the City chlorinates its supply. Untreated well water can hold the trivalent form, which a membrane rejects less well, so a well system sometimes needs an oxidizing step ahead of the RO. That is a testing-first treatment conversation, not an off-the-shelf purchase.
Under the cabinet: what an install involves
A typical under-sink system has five parts you will see: a feed valve teed off the cold line, a sediment and carbon prefilter pair that shield the membrane from grit and chlorine, the membrane, a small pressurized storage tank, and a final carbon polishing stage feeding its own faucet. Some newer units drop the tank and make water on demand.
Two connections matter more than the rest. Reject water leaves through a drain saddle clamped onto the sink drain above the trap, and the faucet should carry an air gap so drain water can never siphon back. A gurgle from the faucet base usually means that drain line needs attention.
Time on site depends on the sink. Drilling a faucet hole in quartz takes longer than reusing a sprayer hole, a run to the ice maker adds tubing, and a cabinet crowded by a disposal may send the tank next door. If the kitchen is being redone anyway, planning RO into a kitchen remodel makes room for all of it. If you only want chlorine taste gone at every tap, whole-house carbon is the better fit.
Keeping the membrane honest
Here is where the TDS pen earns its place. Read the regular cold tap, then the RO faucet. On Tulare’s low-mineral water a healthy membrane still cuts the reading sharply, and when the RO number creeps toward the tap number, the membrane is wearing out. We take a baseline on install day so you have something to compare against.
Prefilters are usually changed yearly, sooner in a busy household, and the membrane every few years. Skipping the carbon prefilter is the expensive mistake, because chlorine in the feed slowly damages a thin-film membrane. RO water also runs lower in pH than the City’s 8.5 average, and a remineralizing cartridge is an easy add if you prefer the old taste.