Four checks before you call, and one thing not to do
When a private well stops, a few minutes of looking tells us a great deal, and it may save you a callout.
- The breaker. Find the well circuit in the panel. If it has tripped, reset it once. If it trips again, leave it off.
- The tank gauge. Read the gauge on the pressure tank. Near zero with the breaker on means the pump is not delivering. A normal reading with no water at the taps points somewhere else in the house.
- The pressure switch. Stand near it while someone opens a faucet. A click followed by the hum of a pump tells us the controls are working. A click and silence points to the pump, the control box or the wire.
- What the water did last. Air, sputtering or sand just before the flow died is the classic sign of a pump that ran out of water to lift, not one that simply broke.
The thing not to do is let a pump run when nothing is coming out. A pump running dry can overheat quickly. Switch it off at the breaker and call us.
Pumps set for a water level that is no longer there
The question we end up answering most often around Exeter is not “is the pump broken” but “is there still enough water above it”.
Private wells here draw from the Kaweah Subbasin, groundwater that moves southwest out of the Sierra Nevada and is recharged mainly by the Kaweah River. The City of Exeter’s own water plan says the subbasin has been in overdraft for many years. Citing state data, it records the average water level falling nearly 12 feet from 1970 to 2000, with a low point in 1995 some 35 feet below 1970 levels, and it notes the City itself may need to deepen wells if a drought drags on. The City’s wells run from 296 to 620 feet deep. If your household well is shallower than that, it has less room to absorb a falling water table.
A pump that was set with a comfortable margin when the well was drilled can, years later, sit only a little below the water. It works through winter, then starts sucking air during long summer run times, when heavy seasonal pumping draws the level down. That pattern, failing in the evening and recovering by morning, is the fingerprint we look for.
There is also a policy side. The subbasin is managed under the Sustainable Groundwater Management Act. Its three groundwater agencies have adopted protections for domestic wells and a mitigation program for them. Exeter Irrigation District has also proposed a Yokohl Creek recharge project northeast of town, at the planning stage, which will not help a dry tap this week.
Finding the fault without pulling anything
Most well calls are electrical, and electrical faults can be found from the surface. We check voltage at the pressure switch and the control box. On three-wire pumps the starting capacitor and relay live in that box above ground, and a failed capacitor is a common, quick repair.
Then we measure amp draw with the pump running. Low amps can mean the pump is running without enough water, or a broken coupling. High amps suggest a motor straining against sand or wear. An insulation test on the wire tells us whether a splice down the well has failed.
Rapid on-off cycling is often not the pump at all. A waterlogged pressure tank makes a healthy pump start and stop dozens of times an hour, and a new tank is a much smaller job than the pump it is quietly wearing out.
When the pump has to come up
If the tests point down the well, we pull the pump with its drop pipe and wire. We look at the motor, the impellers for sand wear, the check valve and the splice. We measure the static water level and the drawdown while pumping, which is the information that decides where the pump goes back.
If there is water below the old setting, the pump can often go lower, sometimes with a model built for more lift. A dry-run protection device that shuts the pump off when it loses water is worth adding where levels are marginal. When the pump is back in, the well is disinfected, flushed and returned to service.
What is not a pump job
If the water has dropped near the bottom of the well, no pump fixes it. Deepening the well or drilling a new one is work for a licensed well drilling contractor, and we will say so rather than sell you equipment that will not reach water. If the problem is water quality rather than quantity, our page on treating nitrate and arsenic in well water is the better starting point.
Call us when the well stops
All Flow Plumbing is based in Exeter, licensed under CSLB #1072777, bonded and insured, and the phone is answered live 24/7. Call (559) 648-6871, tell us what the gauge reads and what you heard, and we will bring the right gear the first time. You get a written price before any work starts.