Match what you see to what has failed
Shower and tub problems look dramatic, but most of them come from a short list of parts. Find your symptom in the left column and you will have a good idea of the job before anyone arrives.
| What you notice |
What is usually behind it |
The usual fix |
| Spray fans sideways or misses you entirely |
Scale blocking the showerhead nozzles |
Clean or replace the head |
| Tub spout keeps running with the shower on |
Scaled or worn diverter gate |
New tub spout or diverter |
| Temperature swings when other fixtures run |
Sticky balancing spool, or an old valve with none |
New cartridge or a modern valve |
| Drip from the head or spout after shutoff |
Worn cartridge seals or washers |
Cartridge or washer replacement |
| Handle stiff, gritty or hard to turn |
Mineral packed into the cartridge |
Cartridge replacement |
| Tub drains slowly and leaves a gray ring |
Hair and soap at the stopper or trap |
Clear the stopper, then the trap |
| Stain or soft drywall on the far side of the wall |
Leak at the valve body or shower arm |
Open access and repair at the source |
Anything in the first two rows you can often handle yourself with a bag of vinegar and an adjustable wrench. The rest involve the valve inside the wall, which is where we come in.
Hot water and the minerals behind the white crust
Exeter’s water comes from groundwater, and it carries dissolved rock with it. The City’s 2025 Consumer Confidence Report lists calcium at an average of 41.2 mg/L and magnesium at 12.88 mg/L, both from 2025 sampling, and the City’s water management plan calls the local groundwater generally a calcium bicarbonate type. Overall hardness in that same report averages 160 mg/L from a 2022 sample, swinging between 110 and 230 depending on which well is feeding you.
Heat changes how those minerals behave. Calcium carbonate comes out of solution far more readily from hot water than cold, so the hot side of a shower takes the worst of it. It settles in three places:
- The showerhead, where water squeezes through dozens of tiny nozzles
- The diverter, a rubber gate in the tub spout that has to seal against a smooth seat
- The mixing cartridge, where hot and cold meet and a spool or disc has to slide freely
That is why a stiff handle, a leaky diverter and a crooked spray so often show up together in the same Exeter bathroom. They are one problem in three spots. Cleaning helps for a while, but a cartridge that has been grinding for months is usually past saving, and a replacement from the original maker is the dependable fix. If the scale is everywhere in the house, ask us whether a water softener is worth it for your home.
Scald protection when the valve is replaced
A shower valve is a safety device as much as a tap. The California Plumbing Code requires new shower and tub-shower valves to be pressure-balancing, thermostatic, or a combination of the two, with a handle limit stop adjusted so the mixed water cannot exceed 120 degrees Fahrenheit.
Some older bathrooms still run on two-handle valves with no balancing at all. Those are the showers that scald when a toilet flushes. When we replace one, the new valve brings that protection with it, and we set the limit stop on site rather than leaving it at whatever the factory chose. If the water is still too hot at the limit, the next stop is the tank itself, and water heater repair covers thermostats and settings.
Tubs have their own weak spots
Not every bathtub problem is about the valve. The parts below the water line fail too:
The stopper and the drain body collect hair and soap until the tub drains slowly. Clearing the stopper fixes most of these. When it does not, the clog is in the trap or branch line, and drain cleaning gets it moving without chemicals.
The overflow plate has a gasket behind it. When that gasket hardens and cracks, a full bath leaks into the floor or the ceiling below every time someone fills it past the overflow. The tub spout slips or screws onto a pipe stub, and if it loosens, water runs back into the wall. Both are small parts with outsized consequences.
Older showerheads and the 2.5 gallon limit
California’s water-conserving fixture law, SB 407, covers homes finished on or before the first day of 1994. Under it, a showerhead that flows more than 2.5 gallons per minute is noncompliant. Sellers must disclose noncompliant fixtures, and a permitted alteration to a single-family home needs them replaced before final approval.
A large share of Exeter’s housing was built before that date, so an original showerhead in a hall bath is worth checking, particularly before a sale. If you are planning a full bathroom remodel, fold the showerhead, valve and tub fittings into the same scope.
Book shower or tub repair in Exeter
A bathroom that cannot be used gets a same-day slot, and since we work out of Exeter ourselves, you are not waiting on a crew driving in from another city. You get a diagnosis first and a written figure before any work begins, which stays as written unless you sign off on something different. Someone picks up day or night, and every job runs under our license, CSLB #1072777.
Describe the symptom when you dial (559) 648-6871. It often tells us which cartridge to bring.