When the alarm goes off, do this first
A high-water alarm means the basin is filling faster than the pump is emptying it, or the pump has stopped altogether. The alarm is set to sound before the basin overflows, so you have a little margin, but not much.
- Stop running water anywhere that drains to the basin. If you are not sure which fixtures those are, hold off on all of them: no flushing, no showers, no laundry, no dishwasher.
- Silence the buzzer with the switch on the panel if it has one. That quiets the noise and fixes nothing, so leave the rest of the panel alone.
- Check the breaker for the pump circuit, and whether the pump plugs into an outlet that has tripped. Reset either one only if the floor around you is completely dry.
- Listen near the basin. A hum with no sound of water moving points to a jammed impeller or a closed valve. Silence points to power, the float switch or the motor.
- Leave the sealed lid on. The basin holds raw sewage and sewer gas, and nothing inside it is safe to handle with the lid off and the pump live.
Then call us. If the reset brought the pump back and it emptied the basin, call anyway. Whatever tripped it is likely to do it again.
Exeter’s sewer runs on pumps too
Most of the time, sewage moves by gravity. A pipe sloped downhill carries waste away from the house with no help at all. Gravity has one catch: it only works while there is somewhere lower to go.
The City of Exeter’s own system shows how far that catch reaches. Eight lift stations sit along the City’s collection network, which stretches past 36 miles of pipe between four inches and three feet wide. By the time it all arrives at the treatment plant, that is about 800,000 gallons a day, finished off in ponds where the treated water soaks into the ground or evaporates. On flat valley ground, a sewer that keeps sloping downward eventually sits too deep to build and maintain, so a lift station pumps the flow back up and lets it start falling again.
A house works on the same physics at a smaller scale. When a toilet, shower or washer sits lower than the point where the home’s drain line heads out to the sewer, its waste has nowhere lower to go. An ejector pump does for that room what a lift station does for a neighborhood. It collects the flow in a sealed basin and pushes it up to a height where gravity can take over.
Most Exeter homes drain entirely by gravity and will never need one. The ones that do usually have a room or an addition set below the main drain, or an outbuilding that sits lower than the line it ties into.
Your pump, your responsibility
The City looks after its lift stations. Your ejector is another matter. It sits on private property and feeds your own sewer connection, and section 13.12.060 of Exeter’s municipal code makes the owner the one who keeps laterals and connections working and pays to do it. It also leaves the owner answerable for harm that follows from neglect, which matters if a failed pump sends sewage into a tenant’s unit or a neighbor’s space.
In practice the pump deserves the attention you would give a water heater: a check now and then, an alarm that actually works, and a plan for when the power goes out. Private sewer work is done to the current California Plumbing Code, and we pull permits where the work requires them.
What is inside the basin, and what usually fails
An ejector system is a handful of parts, and each one fails in its own way.
- The float switch tells the pump when to start and stop. Wipes, grease or a shifted pump can trap it, so the pump never starts or never stops.
- The pump has an impeller built to pass solids, but rags, wipes and paper towels still wrap it until the motor hums and nothing moves. A motor that has been straining long enough eventually burns out.
- The check valve on the discharge pipe keeps pumped sewage from falling back into the basin. When it fails, the pump moves the same water again and again and runs far more often than it should. A loud bang as the pump shuts off often comes from this valve.
- The vent lets air in and gas out as the basin fills and empties. A blocked or missing vent means slow pumping and odors.
- The lid and its gaskets keep the gas inside. A cracked gasket is a common reason a room smells of sewage with nothing leaking.
- The alarm is the only warning you get. Plenty of older systems have one that has never been tested, or none at all.
Repair, replace, or rethink
A stuck float or a failed check valve is usually a repair. An old pump with a burned motor, or one undersized for the fixtures it serves, is usually a replacement, and that is the moment to add an alarm if there is none, fit a proper shutoff valve and confirm the vent works. If you are planning a new room below your drain line, talk to us before the layout is final, because the fixtures and the pump should be designed together as part of the plumbing for a bathroom addition.
An ejector is not a sump pump, and the two are not interchangeable. A sump pump moves groundwater and stormwater, while an ejector handles sewage. And if ordinary gravity drains elsewhere in the house are slow as well, the trouble may sit further down the line, where clearing the main drain comes first.
A full basin cannot wait until morning
If the alarm is sounding or the lowest drain is filling, call (559) 648-6871 at any hour. A live person answers, and our crew starts from right here in Exeter. Night work is billed at an after-hours rate that you hear before we roll, and the repair price is in writing before work begins. State license CSLB #1072777, bonded and insured.