What the number on a TDS pen means in Exeter
A handheld total dissolved solids meter is behind a lot of the reverse osmosis calls we get. Someone dips it in a glass of tap water, sees a reading in the hundreds and assumes the worst.
Here is the context. The City of Exeter’s 2025 water quality report puts average TDS at 388 mg/L, with results from 330 to 440 depending on the well. The aesthetic standard is 1,000 mg/L. Exeter’s water is moderate, not heavily loaded. Most of what a pen picks up is ordinary dissolved mineral, including sodium, chloride and sulfate, which the City reports at averages of 47.6, 43.6 and 26.6 mg/L.
A pen cannot tell you which substances are in the glass, only roughly how much is dissolved in total. It earns its keep after an install. A healthy membrane drops the reading sharply, and if the number at the RO faucet starts drifting back toward the tap reading, the membrane or a seal is due for service.
The City’s 2025 report, read with a membrane in mind
These are the lines from the Exeter report that people most often ask an RO system to deal with.
| What the City reports |
2025 average |
Limit |
What a certified RO unit does |
| Total dissolved solids |
388 mg/L |
1,000 mg/L (aesthetic) |
Lowers it sharply |
| Arsenic |
1.9 ug/L |
10 ug/L |
Reduces it, per its data sheet |
| Hexavalent chromium |
1.78 ug/L |
10 ug/L |
Reduces it, per its data sheet |
| Nitrate (as nitrogen) |
5.58 mg/L |
10 mg/L |
Reduces it, per its data sheet |
| Fluoride (natural) |
0.26 mg/L |
2.0 mg/L |
Removes most of it |
The regulated substances above were under their legal limits in the City’s report. So the honest framing is that RO lowers trace constituents further and improves taste at the kitchen tap. It is not fixing water that fails a standard.
When you compare units, look for NSF/ANSI 58 certification and read the performance data sheet. It lists each substance the unit was actually tested to reduce. A box that says “removes heavy metals” without naming arsenic or chromium is not a claim you can hold anyone to.
Nitrate, the line most Exeter callers ask about
Nitrate has a local history, so it gets its own section. The 2025 report shows nitrate as nitrogen averaging 5.58 mg/L against a legal limit of 10, with a range from 1.2 to 16. That 16 came from one sample taken on July 1, 2025, from a well the City was trying to bring into service. The well was not put into service, its water was never pumped into the distribution system, and the state Division of Drinking Water issued no violation. Earlier, in 2022, the City sent out a nitrate notice after Well 6 tested at 11 ppm, and ran that well only as needed while Well 9 was repaired.
Reverse osmosis is one of the standard point-of-use methods for lowering nitrate. Inside city limits you are on the City’s monitored supply. On a private well outside town the picture can be very different, and a certified lab test comes before any equipment. Our page on treating nitrate and arsenic in private wells covers that properly. If someone in the home is pregnant or mixing infant formula, read the City’s report and ask your doctor. We install equipment, but medical advice is not ours to give.
What actually goes under your sink
A home RO system is several stages in a row. A sediment cartridge catches grit. A carbon cartridge removes chlorine, which matters in Exeter because the City chlorinates its wells and chlorine degrades the thin-film membrane. The membrane does the main work. A pressurized storage tank holds treated water so the faucet has usable flow, and a carbon polisher takes off any taste the tank adds. Some systems finish with a remineralizing stage that puts a little calcium back for flavor.
Fitting it means a cold-water supply valve, a dedicated faucet, a drain saddle on the sink tailpiece and an air gap that keeps drain water from ever finding its way back into the system. Stone counters get drilled with the right bit, or we use the old sprayer hole.
When RO is the wrong purchase
If the only complaint is chlorine taste or smell at every tap, whole-house carbon filtration treats the shower and laundry too, while RO serves one faucet. If white crust on fixtures is the problem, RO does nothing for the shower head, and a water softener is the right tool. And if your water tastes fine and only the pen reading worried you, the numbers above may be all you needed. You may not need us for this one.
Getting RO installed in Exeter
All Flow Plumbing has been based in Exeter since 2021, licensed under CSLB #1072777, bonded and insured, with a 4.9 average on Google. Call (559) 648-6871 and tell us why you are thinking about RO. We will measure your water, explain the options that fit, and put the exact price in writing before we drill a single hole. It stays that price unless you approve a change.